Tag Archives: sustainability

Large Angle Grinder

Large Angle Grinder

Milwaukee 6088 30 7 Inch 9 Inch Large Angle Grinder wit
Milwaukee 6088 30 7 Inch 9 Inch Large Angle Grinder wit
Paypal   US $175.99
Bosch 7 Large Angle Grinder 1974 8 NEW
Bosch 7 Large Angle Grinder 1974 8 NEW
Paypal   US $216.98
Bosch 7 Large Angle Grinder w Lock On 1873 8F NEW
Bosch 7 Large Angle Grinder w Lock On 1873 8F NEW
Paypal   US $176.98
Bosch 7 3 HP 8500 RPM Large Angle Grinder 1873 8 NEW
Bosch 7 3 HP 8500 RPM Large Angle Grinder 1873 8 NEW
Paypal   US $166.98
DeWalt D284939 9 Guard For Large Angle Grinder Type 27 Grinding Wheels
DeWalt D284939 9 Guard For Large Angle Grinder Type 27 Grinding Wheels
Paypal   US $21.00
DeWalt D28474W 7 Heavy Duty Large Angle Grinder
DeWalt D28474W 7 Heavy Duty Large Angle Grinder
Paypal   US $151.15
BOSCH 7LARGE ANGLE GRINDER W VIBRATION CONTROL 1873 8
BOSCH 7LARGE ANGLE GRINDER W VIBRATION CONTROL 1873 8
Paypal   US $129.95
Fein 7 8500 RPM Large Angle Grinder WSG 20 180 NEW
Fein 7 8500 RPM Large Angle Grinder WSG 20 180 NEW
Paypal   US $286.98
Fein 9 6600 RPM Large Angle Grinder WSG 20 230 NEW
Fein 9 6600 RPM Large Angle Grinder WSG 20 230 NEW
Paypal   US $286.98
View Page:   1  2  3  4  5


should i have resistance on windings of angle grinder.?

hi, my angle grinder was not working so i checked resistance on windings and got zero. i then checked the resistance of windings on a much smaller angle grinder that works and i got some resistance, about 2k. can i take it windings on larger angle grinder are gone.?
dont think the motor has commutator. i had the windings completely removed from agle grinder and took reading from there . i was just reading up elsewhere and it was saying readings can be very low and once there is not an open cicruit and both windings read the same it should be okay. so i am beginning to think problem could be elsewhere .thanks for your help
dont think the motor has commutator. i had the windings completely removed from agle grinder and took reading from there . i was just reading up elsewhere and it was saying readings can be very low and once there is not an open cicruit and both windings read the same it should be okay. so i am beginning to think problem could be elsewhere .thanks for your help

Sounds like it, but has the motor got a commutator with carbon brushes. It could be that they have worn out or got jammed in the brush slides, this would have the effect of an open circuit and stop power getting to the windings. Or, where have you measured the resistance from? - If you have measured it from the plug, is the switch faulty?